后面板  

自动电器安规综合测试仪(五合一) Zentech 9032C

厂家: 台湾铨华

详细指标 pdf文档

Zentech 9032C为综合电子安规分析仪,可执行交直流耐压、绝缘电阻、接地电阻及动态泄漏电流,五项电子安规测试功能,多应用于电子成品之安全规格检测,9032C可直接外插或内建动态泄漏电流自动扫描仪(A190305),简易的装置及操作,量测复杂的安规要求,提高生产测试效率。

仪器菜单选项

交流耐压测试 - WAC
  1. High = Disable
    Scan Box - 1 Channel
  2. Voltage = 0.05 - 5kV
  3. High Limit = 0 - 40mA
  4. Low Limit = 0 - 40mA
  5. ARC Limit = 0 - 40mA
  6. Test Time = 0 - 999s
  7. Ramp Time = 0 - 999s

 

直流耐压测试 - WDC
  1. High = Disable
    Scan Box - 1 Channel
  2. Voltage = 0.05 - 6kV
  3. High Limit = 0.0001 - 20mA
  4. Low Limit = 0 - 20mA
  5. Charge Low = 0 - 20mA
  6. ARC Limit = 0 - 20mA
  7. Test Time = 0 - 999s
  8. Ramp Time = 0 - 999s

 

泄漏电流测试 - LC
  1. Device =
    D0 OFF
    D1 UL544NP
    D2 UL544P
    D3 UL1563
    D4 UL2601-1
    D5 UL1950
  2. Line =
    L0 NORMAL
    L1 REVERSE
    L2 SF-NORMAL
    L3 SF-REVERSE
  3. High Limit = 0.0001 - 6.000mA
  4. Low Limit = 0 - 9.999mA
  5. Power =
    VOLTAGE
    CURRENT
    VA
  6. Voltage High = 0 - 300V
  7. Voltage Low = 0 - 300V
  8. Test Time = 0 - 999s
接地电阻测试 - GR
  1. High = Disable
    Scan Box - 1 Channel
  2. Current = 1-30.00A
  3. High Limit = 0.1 - 510mohm
  4. Low Limit = 0 - 510mohm
  5. Test Time = 0 - 999s
  6. Ramp Time = 0 - 999s

 

绝缘电阻测试 - IR
  1. High = Disable
    Scan Box - 1 Channel
  2. Voltage = 0.05 - 1kV
  3. High Limit = 0.1 - 50000Mohm
  4. Low Limit = 0 - 50000Mohm
  5. Test Time = 0 - 999s
  6. Ramp Time = 0 - 999s

 

 

警告

一旦按下"start"键,测试开始,在测试过程中和测试停止后的短时间内,

禁止触碰以下几个位置,以防触电。

1 高压输出端

2 高压输出端的接线

3 连接的被测物

 

开关机之前一定要断开高压测试端连接的被测物。

开关机之间一定要间隔几分钟,禁止连续开关电源,避免造成仪器自身损毁。


咨询电话: 132- 4173- 5460 , 邮箱: 52634729@QQ.com